What is an AMF Control Panel?

The AMF control panel features electronic devices that allow you to monitor the functions of the backup power generator.

WHAT IS AN AMF CONTROL PANEL PDF

An AMF control panel is not an AMF panel.

WHAT IS an AMF CONTROL PANEL VIDEO TUTORIAL

You can purchase an old generator as old as 40 years! Our panel will manage all of it. Follow our tutorial.

how an AMF panel actually work^Are you confused about AMF and ATS panels?

We manufacture generator control panels since 1984. You will find on the internet hundreds of useless information about this matter.what is the difference between AMF and ATS panels?


Stay tuned on this page if your business is to make AMF and ATS panels.

The AMF control panel is a processor-based electronic board with miscellaneous components: LED indicators, displays, relays, electronic components, and terminal blocks. it is usually assembled in a rugged IP62 enclosure. This is the basic component of an AMF panel.

If your business is installing standby power generators, visit the page 

AMF PANELS PRICE LIST


BEk3 AMF Control Panel Price

You can pay online or ask for a Proforma Invoice and pay via bank transfer

 129€

FREE-SHIPPING WORLD-WIDE

20 DAYS DELIVERY TIME 

SUPPORT

+39 335 70 77 148

[email protected]

SALE TERMS


MAYBE YOU ARE INTERESTED IN TWO PIECES. THERE YOU ARE OUR OFFER

PURCHASE 2 PCS

 99€/each

FREE-SHIPPING WORLD-WIDE

20 DAYS DELIVERY TIME

You can pay online or ask for a Proforma Invoice and pay via bank transfer

SUPPORT

+39 335 70 77 148

[email protected]

We apply special discounts of 20% 40% for bulk orders


BERNINI DESIGN SALE TERMS


AMF Control Panel Description

The BeK2 AMF control panel features a 128X64 graphic display, operating in a temperature range between -15°C and +50°C, indicating parameters, alarms, and miscellaneous functions.  The AMF control panel measurements include Vac, Aac, Vdc, kVA, kVar, kW, Energy, Pf, Hz, hour count, R.p.m., Oil Pressure, Engine Temperature, Battery Vdc (Engine), and Fuel Level.

The AMF contol panel is the user interface of an AMF panel

The BeK2 control panel complies with NFPA-110 / NFPA-99 specifications. The Be-K2 controller is the best choice when making an AMF panel that interfaces with an old or second-hand generator. The BeK2 features 10 programmable inputs. You can set the input in analogue or digital mode to perform dedicated tasks.  The 7-static short-circuit-proof outputs are fully programmable. The rich set of over 150 adjustable settings makes this AMF control panel the most advanced piece of AMF controller available today in the market.


How to get the most from an AMF control panel

Follow our advice. We have made AMF panels since 1984. We have 40 years of experience servicing AMF panels for industrial, telecom and specific applications.

VISIT OUR AMF PANEL MANUFACTURING WEBSITE

STEP 1

Never install an AMF control panel on the generator. It would help if you carried all 400V cables from the mains into the generator. This is extremely dangerous in case of lightning. You will get 100% trouble on your generator.never install an AMF controll panel on a generator

STEP 2

This is the right way to manufacture a long-term reliable AMF panel. The utility power will never affect the DC circuits of the generator. All overvoltage will be shut down inside the panel. It will act as a Faraday cage,

THIS IS THE WAY TO CONNECT AN AMF CONTROL PANEL


THE BEK2 IS A  "ROCK SOLID " AMF CONTROL PANEL WITH AN ENCLOSURE MADE OF STEEL

We do not use plastic materials in our reliable AMF control panels. The enclosure of the BeK2 control panel is made of zinc double-coated steel. Zinc is a heavy element, and when alloyed with other metals, it provides better corrosion resistance, stability, dimensional strength and impact strength.

reliable AMF control panels never use plastic covers

The rear cover made of metal is the best solution for shock-proof equipment. It is an excellent protection against electromagnetic fields by enclosing the 32-bit processor into a Faraday cage. The BeK2 AMF control panel provides an extraordinary advantage over competitors' plastic-based enclosures.


INGRESS PROTECTION IEC60529 SILICON GASKET UV-PROOF

The BeK2 AMF control panel, thanks to a silicon gasket, is IP65-compliant.

IP65 AMF CONTROLLER


INSIDE A BEK2-BASED PANEL OVERVIEW

THE BEK2 AMF PANEL VIEW

[1] Power supply [2] Modbus port  [3] Digital / Analog Inputs [4] Generator & Utility power connections [5] Protection Ground [6] Current transformers


THE CHANGEOVER EXPLAINED

There are two basic solutions to transfer the LOAD to GENERATOR or UTILITY POWER: by contactors and by motorized transfer switches. The matter is quite complex. You can find a tutorial on this link

CONTACTORS VERSUS MOTORIZED SWITCHES

In a few words, we can say that it is preferable to use contactors changeover when the total power is up to 100kVA. Over this power, it is better to use motorized switches. In particular cases, a combination of both is required.

 THIS IS A CONTACTOR-BASED CHANGEOVER

The changeover is made by two contactors capable of carrying the nominal current of the panel. This is in the range from 63 amps up to 250 amps. The contactors are activated and held in position by electric coils. On each contactor three are auxiliary contacts. The two contactors are interlocked. In this way, only one contact can be activated.

THIS IS A CONTACTOR-BASED CHANGEOVER SWITCH

 THIS IS A MOTORIZED-SWITCH-BASED CHANGEOVER

The motorized changeover switch is a complex piece of equipment. An electric motor moves the switch to a desired position. Before closing a circuit, the switch is always placed in the OFF position. The motorized transfer switch can manage an enormous amount of current.  Once the switch is in position there is no current consumption because there are no coils. On the other hand, you can not pretend flexibility of use. It finally requires a special driving electronic board.

THIS IS A MOTORIZED CHANGEOVER SWITCH


AMF control panel wiring diagram based on contactors changeover

The BeK2 AMF control panel governs the system and transfers the load to the generator or mains smoothly and with short downtime. This AMF control panel wiring diagram shows the basic connections of the BeK2 AMF control panel. It monitors all electrical parameters of the utility power and automatically starts the engine via relays. This happens after a mains failure programmed delay (seconds, minutes or hours).

AMF CONTROL PANEL WIRING DIAGRAM

When the engine is cold, the AMF controller waits for a warm-up. The engine will run offload. Once the generator provides the correct frequency and voltage, the controller transfers the load from the mains to the generator. This could be done via a contactor changeover or a motorized transfer switch, Once the mains has been restored, the AMF control panel will connect the load to the mains automatically. After a time delay, the engine is then stopped.


HOW DOES THE AMF CONTROL PANEL WORK?

The BeK2 control panel activates the KG (contactor of the generator) using the KM-AUX and KG-PILOT contacts.. The KM-AUX are the auxiliary contacts fitted on the body of the utility power contactor (KM). When the KM is open, the KM-AUX contacts enable the KG. The AMF control panel finally activates the KG via the KG-PILOT relay. When the AMF control panel switches the generator to the utility power, the user observes a short ‘power outage’. Normally it is about 2 seconds. This is the typical behaviour of the automatic transfer switch: BREAK-BEFORE-MAKE.


AMF CONTROL PANEL UTILITY POWER-LOAD

The KM contactor connects the LOAD to the utility power. The coil of the KM energizes via the KG-AUX and KM-PILOT contacts. The KG-AUX auxiliary contacts have a mechanical connection with KG. The contacts close when the KG opens. The KM-PILOT is the utility power control relay. This relay is OFF when the mains is within the settings. Using the normally closed contacts, we prioritise the utility power in case the AMF controller is damaged or without supply. In case of utility power failure, the AMF controller energizes the KM-PILOT. The KM-PILOT contacts will open the KM. Once the KM is open, the auxiliary contacts KM-AUX will close.


A USER-FRIENDLY AMF CONTROL PANEL

[1] Multi-functions button [2] Shut down indicator [3] Engine control panel [4] Changeover manual control A USER-FRIENDLY AMF CONTROL PANEL

[5] Mode of operation selection [6] AMF panel indicators [7] Navigation buttons [8] LCD Display


HOW TO SET THE AMF CONTROL PANEL

Despite the possibility to set up the controller by using the navigation buttons and display, the BeK2 control panel offers a USB 2.0 connection. You can plug a B-TYPE male connector on the Be-K3 and an A-TYPE  male connector on your computer. The software is provided free of charge.

Connect an USB plug to configure the AMF control panel


AMF CONTROL PANEL GENERAL FEATURES

80 OPTIONS FOR EACH ADJUSTABLE OUTPUT

5-PROGRAMMABLE LE RELAY OUTPUTS

 35 OPTIONS FOR EACH ADJUSTABLE INPUT

9-PROGRAMMABLE DIGITAL INPUTS

200 EVENTS LOG HISTORY TAGGED BY R.T.C.


600VAC 3-PHASE VAC MONITORING

EARTH FAULT MONITORING

OVER 150 ADJUSTABLE SETTINGS


14-BUTTON INDUSTRIAL CONTROL PANEL

GRAPHIC 128X64 LCD DISPLAY

GENERATOR INSTRUMENTS

ENGINE INSTRUMENTS


 DRIVES MOTORIZED CIRCUIT BREAKER


AMF CONTROL PANEL SPECIFICATIONS

Supply voltage:

5.5Vdc to 36Vdc, 50-150mA

Protection:

internal 300mA thermal fuse

Dimensions:

 192mm X 144mm X 40mm

Panel Cut-out:

187mm X 139mm, indoor operation

Operating temperature range:

-25 deg C up to +70 deg C

Humidity range:

5% up to 95% non-condensing

Weight:

710 grams

Ingress Protection:

IP62

General design:

ECC 89/336, 89/392, 73/23, 93/68, IEC 68-2-6

Certification:

CE

Static output characteristics:

300mA/100Vdc short circuit proof, negative.

Supply output for relays:

 Max 1A at V battery minus 1Vdc (short circuit proof)

Mains and Generator voltage input:

Nominal Voltage input: 70 Vac-600Vac

Overvoltage:  4KVac phase to neutral

Measurement precision:

+/- 2%. Input impedance: 2 Mega Ohm

Current transformer input size:

10/5Aac up to 9900/5Aac

Maximum admissible permanent current:

7Aac

Measurement precision:

+/- 2%. Internal resistance: 0.05 Ohm

Digital inputs Open circuit voltage:

Battery voltage minus 2V - Trigger level: < 2V 

Charger alternator monitoring:  

Operating voltage up to 36Vdc/3W, accuracy +/- 5%


CONTROL PANEL OUTPUTS

On the removable connector JC you are required to wire auxiliary relays. The BeK2 AMF control panel provides a common supply rail (JC8) suitable for automotive relays providing at the same time over-voltage protection, short circuit protection, and EMI protection. You are required to use 90-200 OHM DC coil relays (12 V or 24 according to your engine battery).

the AMF control panel drives DC relays

The flywheel diodes are included in the controller.


CONTROL PANEL INPUTS

The connector JF is used for the ANALOG and DIGITAL sensor fitted on the engine. You can use various sensors. Default settings allow the use of VDO-CONIINENTAL devices. You can change the setup in a range 0 up to 2000OHM.

Connection sensors to AMF control panel
Vac CONNECTIONS

The JA removable plug is used to connect the Mains & Generator voltages. Electrical parameters must be in the range of 80-600V and 20-99HZ. The removable connectors JP and JL are provided for the connection of the CURRENT TRANSFORMERS suitable for the current monitoring of the EARTH FAULT and the current monitoring of the 3-PHASE GENERATOR. Use suitable current transformers for your application.

IT IS MANDATORY TO PROTECT THE CABLES INSIDE THE CABINET! INSTALL 10 AMPS MAX FUSES OR CIRCUIT BREAKERS

AMF CONTROL PANEL GENERATOR CONNECTION

The JA removable plug is used to connect the Mains voltages. Electrical parameters must be in the range of 80-600V and 20-99HZ.

THE MAINS CONNECTION

Connect the current transformer on the LOAD side. In this way you will get current measurements all the time, When you set an overload warning or shutdown, only the measurement from the generator will cause the alarm.

CONNECTING THE CURRENT TRANSFORMERS


AUTO MODE OF OPERATION

­­­­­­­­­­­­­­­­Push the [AUTO] push button until the yellow LED illuminates. The engine starts when the BeK2 detects a Mains failure (see section 9.01 for settings). The Mains circuit disconnects the LOAD after the [MAINS BREAKER] timing. After the  [WARM UP]  time if the voltage and frequency are within the settings, the circuit breaker of the Generator will close. If the Mains restores, the KG will open. The KM will close following a programmed  [KM CHANGEOVER]  timing. The engine will stop after a  COOL DOWN ]  time. If the engine shuts down, because of an alarm, the KM closes independently of the Mains status if the  NFPA-110 ]  is on, otherwise, the KM will close only if the parameters of the Mains are within the programmed settings. In AUTO mode, the BeK2 will periodically test the engine if the periodic test is correctly programmed. During the test, the yellow LED of the AUTO mode will continue to blink. The BeK2 can start and stop the engine if the remote control is activated.


TEST MODE

Push and hold the [AUTO] push button until the yellow LED starts to blink. The BeK2 will start the engine and transfer the load to the Generator only in case of Mains failure if not otherwise programmed by the parameter [KG TEST CONTROL]. To exit the TEST mode, push the [AUTO] push button shortly or select another mode of operation.


BERNINI DESIGN SRL

ITALY

Industrial Park

46035 OSTIGLIA

[email protected]

SALE TERMS

SUPPORT

+39 335 70 77 148